OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 114 of 193
H90202-7e-ID-B.docx
BANK:
The BANK addresses a specified memory bank of the target device. The following banks
are acceptable:
BANK
Value
Main
0x01
MODE:
The MODE controls the command. The following flags are defined:
Bit
7
6
5
4
3
2
1
0
Function
0
ALL
0
0
0
LOC
LOC:
specifies the location of the configuration block
b000
RAM
b001
EEPROM
ALL:
specifies to read the complete configuration from RAM or EEPROM
b0
configuration to be read specified by CFG-ADR and CFG-N
b1
read complete configuration. CFG-ADR and CFG-N ignored
CFG-ADR:
In Request protocol: First block address of the required configuration blocks.
In Response protocol: block address of the following configuration data which builds to-
gether a dataset, repeated CFG-N times.
CFG-N
:
In Request protocol: Number of configuration blocks to be read.
In Response protocol: Number of returned datasets which consists of a block address
and related configuration data.
0x00:
all configuration blocks
0x01:
one configuration block