9.8. [0x72] Set Output
The command Set Output serves temporary limited or unlimited activation of the outputs of the
Reader.
Each output takes the state defined by the byte OUTx-mode for the period of time (OUT-TIME)
included in the protocol. The flashing frequency is defined by the byte OUTx-frq. Via this protocol
the outputs can be switched on or off for the indicated period of time. If the Reader receives a
command Set Output, all times that have been active until then are being overwritten by the new
times included in the protocol if they are
>
0.
Host
→
Reader
Byte
1
2
3
4
5
Contents
n
COM-ADR
[0x72]
Mode
OUT-N
6
7
8-9
n-1...n
OUT-NR
OUT-S
OUT-TIME
CRC16
Repeated OUT-N times
Host
←
Reader
Byte
1
2
3
4
5...6
Contents
6
COM-ADR
[0x71]
STATUS
CRC16
Mode:
0x00
0x01 (reserved)
OUT-N:
Defines the number of output records.
32