OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 178 of 193
H90202-7e-ID-B.docx
TR-DATA2:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
ANT_Ext
-
-
-
IN
IN:
b0:
no Input will be stored
b1:
Inputs will be stored
ANT-Ext: Antenna Extended
Antenna number with RSSI
NOTE:
If the ANT bit in TR_DATA (CFG11) is set in Buffer-Info-Mode:
When a Transponder is detected by multiple antennas, only one data set is stored. The Va-
lid-Time is only set at the first detection. If a data set is transferred to the host and the same
Transponder is detected in another antenna but the Valid-Time has not yet elapsed, no oth-
er data set is stored.
If the ANT bit in TR_DATA (CFG11) is not set in Buffer-Info-Mode and a Transponder is de-
tected by multiple antennas, the data set for each antenna is stored.