7.4. CFG3: RF-Interface
The parameters of the CFG3 configuration block contain global Transponder drivers and Reader
settings.
Byte
0
1
2
3
4
5
6
Contents
TAG-DRV
RF-POWER-
ANT1
REG
0x00
DC-Power
0x00
Default
0x0010
0x19
0x06
0x04
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
FREQ_US
0x00
NR_PREFER
RED_CHN
PREFERRED_CHN
Default
0x00
0x0000
0x00
0x00
0x0000
NOTE:
The settings in CFG3 are not affected by the command [0x8C] Reset
TAG-DRV
1
: (Transponder.Driver.UHF.Drivers
)
Defines the Transponder types that are operated by the Reader.
Byte
0
1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Driver
0
0
0
0
0
0
0
0
0
0
0
E
0
0
0
0
b0:
Driver for the Transponder type is inactive
b1:
Driver for the Transponder type is active
.E: (Transponder.Driver.UHF.EPC_Class1Gen2)
EPC class 1 Gen 2
In principle, only those Transponder drivers should be active that are used in the
actual application. Thus, the reaction time of the Reader for Transponder read- /
write-operations is reduced and the danger of a parasitic Transponder access is
minimized.
NOTE:
Except for the EPC GEN2 driver all other transponder drivers needs an upgrade code first.
The upgrade code must be ordered by your supplier or FEIG ELECTRONIC GmbH.
To operate an ISO 18000-6-C Transponder the EPC GEN2 driver needs to be enabled. This
Firmware Function needs to be activated with an upgrade code first.
5
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = [0x11].