OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 138 of 193
H90202-7e-ID-B.docx
MODE = 0x01:
Byte
5
6
Contents
FLAGS A
FLAGS B
FLAGS A:
Bit
7
6
5
4
3
2
1
0
Function
-
-
Channel
alloca-
tion
RF Power
CONTROL
NOISE
RF-HW
FLAGS B:
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
|
Z|
</>
Ant4
|
Z|
</>
Ant3
|
Z|
</>
Ant2
|
Z|
</>
Ant1
Error Conditions (Flag A and B):
Error
Set condition
Clear condition
Trouble shouting
RF Power
LED 5
RF-HW
RF hardware error
•
CPU reset
OFF
ON
NOISE
The noise in the receiver
channel is very high
•
Select other pre-
ferred channel(s) or
add more preferred
channels (max.
four) in CFG3.
ON
ON
RF Power
CONTROL
RF-Power out of control
range
•
configured Power to
high
•
check cable
ON
ON
Channel allo-
cation
Reader is not able to
detect a free channel
Note:
This Warning is dis-
played only with EU
Reader
•
Select other pre-
ferred channel(s) or
add more preferred
channels (max.
four) in CFG3
ON
ON
|Z|
<>
absolute impedance
value
<< or >>
50 Ohm
•
check cable
•
check antenna
matching
ON
ON