OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 170 of 193
H90202-7e-ID-B.docx
10.2.4. [0x26] Read Permalock Status
This command reads the permalock status of the user memory of an EPC transponder.
REQUEST-DATA
Byte
4
5
1 Byte
EPC_LNG
Bytes
1 Byte
Contents
0x26
MODE
EPC_LNG
EPC
BANK
1 Byte
A_PW_LNT
Bytes
2 Byte
1 Byte
A_PW_LNG
A_PW
BLOCK_PTR
BLOCK_
RANGE
RESPONSE-DATA (STATUS = 0x95)
Byte
5
Contents
EPC Class1
Gen2 ERROR
RESPONSE-DATA (STATUS = 0x00)
Byte
2 x Block-
Range
Contents
PERMALOCK
_STATUS
MODE:
Bit
7
6
5
4
3
2
1
0
Function
0
0
1
1
0
ADR
ADR:
b000
non-addressed
b001
addressed
EPC_LNG:
EPC_LNG defines the length of the following EPC field.