OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 156 of 193
H90202-7e-ID-B.docx
UID_LF:
If this bit is set the parameter UID_LNG must inserted into the protocol.
b0:
The protocol UID_LNG doesn't include the UID_LNG byte and
the UID field has a fixed length of 8 byte, from byte 6 to byte 13.
b1:
The protocol includes the parameter UID_LNG. The UID has a variable
length as defined in UID_LNG.
EXT_ADR:
If this bit is set the command includes extended address fields.
b0:
Transponder memory addressing is done by the 1 byte DB-ADR Field.
b1:
Transponder memory addressing is done by BANK and
2
byte DB-ADR
Field
READ_COMPLETE_BANK:
If this bit is set the reader will automatically read out all blocks of the selected
memory bank starting from DB-ADR. If DB-ADR is “0” the complete content of the
memory bank will be read.
b0:
Reader reads out the memory blocks according to the settings for DB-
ADR and DB-N
b1:
Reader reads out all blocks of the selected memory bank starting from
DB-ADR
NOTE:
The read complete bank functionality has following limitations for the individual memory
banks:
EPC Memory:
512 Bit
TID Memory:
512 Bit
User Memory:
16 kBit
Reserved Memory:
64 Bit
MORE_DATA
If the protocol length increases the maximum size of the transfer buffer (
) a
more data request needs to be send.
b0:
no More Data request is send
b1:
More Data request is send