Operation of binder dosing system
BOMAG
90
MPH 122-2
Fig. 189
l
Close the middle spraying section (n) (Fig.
188) once the binder pump pressure gauge (d)
(Fig. 189) and the spraying bar pressure
gauge (a) show increasing pressure.
Fig. 190
l
Set the selector switch for spraying/circulation
(k) (Fig. 190) to position "Circulation".
l
Set the binder quantity potentiometer (m) to
zero flow.
l
Set the reaction water flow quantity potentiom-
eter (l) to stage 5.
l
Open the spraying sections (n).
l
Set the selector switch for spraying/circulation
(k) to position "Spraying".
Fig. 191
l
Close the spraying sections (n) (Fig. 190)
when the reaction water pressure gauge (b)
(Fig. 191) has reached a pressure of at least 4
bar.
l
Set the selector switch for spraying/circulation
(k) (Fig. 190) to position "Circulation".
Starting work
Fig. 192
l
Pre-select the sections (n) (Fig. 192) on the
spray bar.
l
Set the binder quantity potentiometer (m) to
the desired flow.
l
Set the reaction water quantity potentiometer
(l) to the desired flow.
l
Start milling.
l
Set the selector switch for spraying/circulation
(k) to position "Spraying".
l
If necessary regulate the flow rates with the
binder flow rate potentiometer (m).and the re-
action water flow rate potentiometer (l).
Summary of Contents for Bomag MPH 122-2
Page 2: ......
Page 8: ...Table of Contents BOMAG 8 MPH 122 2...
Page 9: ...BOMAG 9 MPH 122 2 1 Technical Data...
Page 13: ...BOMAG 13 MPH 122 2 2 Safety regulations...
Page 24: ...Safety regulations BOMAG 24 MPH 122 2...
Page 25: ...BOMAG 25 MPH 122 2 3 Indicators and Controls...
Page 26: ...Indicators and Controls BOMAG 26 MPH 122 2...
Page 27: ...Indicators and Controls BOMAG 27 MPH 122 2 Fig 9 Fig 10...
Page 49: ...BOMAG 49 MPH 122 2 4 Operation...
Page 82: ...Operation BOMAG 82 MPH 122 2...
Page 83: ...BOMAG 83 MPH 122 2 5 Operation of binder dosing system...
Page 95: ...BOMAG 95 MPH 122 2 6 Maintenance...
Page 124: ...Every 10 operating hours BOMAG 124 MPH 122 2...
Page 130: ...Every 50 operating hours BOMAG 130 MPH 122 2...
Page 172: ...Every 4000 operating hours BOMAG 172 MPH 122 2...
Page 189: ...BOMAG 189 MPH 122 2 7 Trouble shooting...
Page 197: ......
Page 198: ......