Every 250 operating hours
BOMAG
133
MPH 122-2
Fig. 259
l
If the white float (Fig. 259) inside the inspec-
tion glass of the drier/collector unit floats at the
bottom, inform the service department.
i
Note
The refrigerant level is not correct.
l
Refrigerant must be filled up, if necessary
check the air conditioning system for leaks.
Checking the moisture level of the dry-
ing agent
Fig. 260
l
Check the moisture indication pearl (Fig. 260)
inside the inspection glass of the drier/collec-
tor unit.
orange =
Drying
agent
o.k.
colourless
= moisture level of drying agent
too high.
l
Inform the service department. Replace drier/
collector unit, check air conditioning system.
!
Caution
Have the drier/collector unit replaced by the
service department every year before the oper-
ating season.
Checking the condition of the drier/col-
lector unit
!
Caution
According to the regulation for pressure reser-
voirs all pressure reservoirs must be repeated-
ly inspected by a specialist. In this sense
repeated inspections are external examina-
tions, normally on pressure reservoirs in oper-
ation. In connection with this inspection the
drier/collector unit must be visually examined
twice every year. During these inspections
special attention must be paid to corrosion
and mechanical damage. If the reservoir is not
in proper condition it must be replaced for
safety reasons, as a precaution to protect op-
erators and third parties against any danger
arising from the handling and operation of
pressure reservoirs.
!
Danger
Danger of injury!
In case of mechanical damage or corrosion on
this drier/collector unit this unit must be re-
placed, to avoid bursting and further damage.
Fig. 261
l
Check the drier/collector unit (Fig. 261) for me-
chanical damage or rust.
Summary of Contents for Bomag MPH 122-2
Page 2: ......
Page 8: ...Table of Contents BOMAG 8 MPH 122 2...
Page 9: ...BOMAG 9 MPH 122 2 1 Technical Data...
Page 13: ...BOMAG 13 MPH 122 2 2 Safety regulations...
Page 24: ...Safety regulations BOMAG 24 MPH 122 2...
Page 25: ...BOMAG 25 MPH 122 2 3 Indicators and Controls...
Page 26: ...Indicators and Controls BOMAG 26 MPH 122 2...
Page 27: ...Indicators and Controls BOMAG 27 MPH 122 2 Fig 9 Fig 10...
Page 49: ...BOMAG 49 MPH 122 2 4 Operation...
Page 82: ...Operation BOMAG 82 MPH 122 2...
Page 83: ...BOMAG 83 MPH 122 2 5 Operation of binder dosing system...
Page 95: ...BOMAG 95 MPH 122 2 6 Maintenance...
Page 124: ...Every 10 operating hours BOMAG 124 MPH 122 2...
Page 130: ...Every 50 operating hours BOMAG 130 MPH 122 2...
Page 172: ...Every 4000 operating hours BOMAG 172 MPH 122 2...
Page 189: ...BOMAG 189 MPH 122 2 7 Trouble shooting...
Page 197: ......
Page 198: ......