disable sys-health-check
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
637
disable sys-health-check
disable sys-health-check slot <slot>
Description
Discontinues sending backplane diagnostic packets on modular switches.
Syntax Description
Default
Polling is enabled, backplane diagnostic packets are disabled.
Depending upon your platform, when disabling backplane diagnostic packets, the following defaults
apply:
●
BlackDiamond 10808 and BlackDiamond 12804 switches—By default, the system health checker
discontinues sending backplane diagnostic packets and returns the polling frequency to 60 seconds
on the specified slot. Only polling is enabled.
●
BlackDiamond 8800 series switch—By default, the system health checker discontinues sending
backplane diagnostic packets to the specified slot. Only polling is enabled.
Usage Guidelines
When you use this command, backplane diagnostic packets are disabled and no longer sent by the
system health checker.
BlackDiamond 10808 and BlackDiamond 12804 Switches Only.
If you use this command, in addition to
disabling backplane diagnostic packets, the polling frequency returns to the default of 60 seconds for
the specified slot.
If you modify the
interval
in the
configure sys-health-check interval <interval>
command,
the polling frequency is
interval
*10 seconds. For example, if you configured an interval of 7, the
polling frequency is now 70 seconds.
BlackDiamond 8800 Series Switch Only.
If you modify the
interval
in the
configure sys-health-
check interval <interval>
command and later disable backplane diagnostics, the configured
interval for sending backplane diagnostic packets remains. The next time you enable backplane
diagnostic packets, the health checker sends backplane diagnostics packets at the configured interval.
For example, if you configure an interval of 8 seconds, the system health checker sends backplane
diagnostic packets every 8 seconds.
To return to the "default" interval of 5 seconds, configure the frequency of sending backplane diagnostic
packets to 5 seconds using the following command:
configure sys-health-check interval 5
slot
Specifies the slot to disable sending backplane diagnostic packets.