show cfm statistics
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
451
The following is sample output from this command:
Domain/ Port MP eff_level_in/ iff_level_in/ iff_opcode
Association eff_level_out iff_level_out
===============================================================================
dnsname
short ma name 2:1 IE 0 0 0
0 0
2:1 OE 0 0 0
2:2 FF 396
0
===============================================================================
Maintenance Point: (IE) Inward-Facing End-Point, (I) Intermediate-Point,
(OE) Outward-Facing End-Point, (FF) Filter-Function
NOTE: The Domain and Association names are truncated to 28 characters, also the
counters displayed are software counters, i.e. packets blocked by
hardware are not included.
History
This command was first available in ExtremeWare XOS 11.4.
Platform Availability
This command is available only on the BlackDiamond 10808 and 12804 switches.