EAPS Commands
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
1150
Example
The following display shows sample output for the command
show eaps
:
EAPS Enabled: Yes
EAPS Fast-Convergence: Off
EAPS Display Config Warnings: On
Number of EAPS instances: 2
# EAPS domain configuration :
--------------------------------------------------------------------------------
Domain State Mo En Pri Sec Control-Vlan VID Count
--------------------------------------------------------------------------------
d1 Complete M Y 3:8 3:16 c1 (1000) 100
d2 Links-Up T Y 3:8 3:16 c2 (1001) 100
--------------------------------------------------------------------------------
The following display shows sample output for the command
show eaps <eapsDomain>
:
Name: d1
State: Complete Running: Yes
Enabled: Yes Mode: Master
Primary port: 3:8 Port status: Up
Tag status: Tagged
Secondary port: 3:16 Port status: Blocked Tag status: Tagged
Hello timer interval: 1 sec
Fail timer interval: 3 sec
Fail Timer expiry action: Send alert
Last update: From Master Id 00:01:30:f9:9c:b0, at Wed Jun 9 09:09:35 2004
EAPS Domain has following Controller Vlan:
Vlan Name VID
c1 1000
Hello Timer interval:
The configured value of the timer in seconds, specifying the time that the
master node waits between transmissions of health check packets.
Fail Timer interval:
The configured value of the timer in seconds, specifying the time that the
master node waits before the failtimer expires.
Failtimer expiry action:
Displays the action taken when the failtimer expires:
• Send-alert—Sends a critical message to the syslog when the failtimer
expires.
• Open-secondary-port—Opens the secondary port when the failtimer expires.
Displays only for master nodes.
Preforwarding Timer interval:
a
The configured value of the timer. This value is set internally by the EAPS
software. The set value is 15 seconds.
Note: If two links in an EAPS domain go down at the same time and one link
comes back up, it will take 15 seconds for the reconnected link to start
receiving traffic again.
Last update:
Indicates the last time a hello packet is received from the master node.
EAPS Domain has … Controller
Vlans:
Lists the assigned name and ID of the control VLAN.
EAPS Domain has … Protected
Vlans:
b
Lists the assigned names and VLAN IDs of all the protected VLANs configured
on this EAPS domain.
Number of Protected Vlans:
The count of protected VLANs configured on this EAPS domain.
a.
These fields apply only to transit nodes; they are not displayed for a master node.
b.
This list is displayed when you use the
detail
keyword in the
show eaps
command.