Installation
MFC
6.
Connecting the sample water
inlet
Please note
Never use copper tubing.
1
The pressure in the sample water inlet must always be within a
range of min. 0.2 to max. 4 bar. At the same time, the pressure
in the sample water inlet must generally be 0.2 bar higher than
in the sample water outlet.
•
If the preliminary pressure is below 0.2 bar, a pressure
booster pump must be used (see "examples for sample
water extraction with booster pump“ Page 191 and
Page 192).
•
If the pressure exceeds 4 bar, a pressure reducing valve
must be used.
2
To prevent long loop dead times, ensure that the pipes in the
sample water inlet are as short as possible.
3
An external strainer with a mesh width of 0.5 mm is provided
for the sample water inlet.
With hose connection
Please note
The water-tightness of the hose screw connection is only
guaranteed if the following installation instructions are followed!
1
Release the union nut (A) on the hose screw connection.
2
Insert the hose (B) until it hits the hose bushing (D).
A Union nut
B Hose
C Locking ring
D Hose bushing
3
Push the locking ring out until the union nut engages the
connecting threads.
A 30° pitch on this side
B Rounding on this side
D
C
A
B
A
B
Summary of Contents for WALLACE & TIERNAN MFC
Page 1: ...WALLACE TIERNAN MULTI FUNCTION CONTROLLER MFC from version V 2 00 INSTRUCTION MANUAL...
Page 2: ...2 WT 050 580 000 DE IM 0714 MFC Please note Original manual...
Page 6: ...6 WT 050 580 000 DE IM 0714 Introduction MFC 1...
Page 40: ...40 WT 050 580 000 DE IM 0714 Description MFC 3...
Page 247: ...MFC Certificates 10 247 10 Certificates...
Page 248: ...248 WT 050 580 000 DE IM 0714 Certificates MFC 10...
Page 249: ...MFC Certificates 10 249...
Page 250: ...250 WT 050 580 000 DE IM 0714 Certificates MFC 10...
Page 262: ...262 WT 050 580 000 DE IM 0714 Settings table MFC 11...