ProNet
Series
AC Servo User's Manual
- 88 -
4.5.6 S-curve Risetime
Pn309
S-curve Risetime
Setting Range
Setting Unit
Factory Setting
Setting Validation
0
~
10000
1ms 0 Immediately
4.5.7 Using the Zero Clamp Function
(
1
)
Zero Clamp Function
The zero clamp function is used for systems where the host controller does not form a position loop for the speed
reference input. When the zero clamp signal
(
/P-CON
)
is ON, a position loop is formed inside the servo drive as soon as
the input voltage of the speed reference (V-REF) drops below the servomotor zero clamp speed. The servomotor ignores
the speed reference and quickly stops and locks the servomotor.
The servomotor is clamped within ±1 pulse when the zero clamp function is turned ON, and will still return to the zero
clamp position even if it is forcibly rotated by an external force.
Speed