5.1.6 Operation in Monitor Mode
The monitor mode allows the reference values input into the servo drive, I/O signal status, and servo drive internal status
to be monitored.
■
Using the Monitor Mode
The example below shows how to display the value (1500) stored in Un001.
1.
Press MODE key to select the monitor mode.
2.
Press the INC or DEC key to select the monitor number to display.
3.
Press the ENTER key to display the data for the monitor number selected at step 2.
4.
Press the ENTER key once more to return to the monitor number display.