ProNet
Series
AC Servo User's Manual
- 82 -
4.5 Operating Using Speed Control with Analog Reference
4.5.1 Setting Parameters
Parameter Meaning
Pn005
H
.□□0□
Control mode selection:Speed control(analog reference)(factory setting)
Pn300
Speed Reference Input Gain
Setting Range
Setting Unit
Factory Setting
Setting Validation
0
~
3000
rpm/v 150
Immediately
Sets the analog voltage level for the speed reference (V-REF) necessary to operate the servomotor at the rated speed.
■
EXAMPLE
Pn300=150
:
1V input is equivalent to the servomotor speed of 150rpm (factory setting).
Speed
Position
Torque