ProNet
Series
AC Servo User's Manual
- 166 -
Parameter
No.
Name Unit
Setting
Range
Factory
Setting
Setting
Invalidation
3:2
nd
order filter
Pn311
S form selection
—
0~3
0
Immediately
Pn312
DP communication JOG speed
rpm
-6000~6000
500
Immediately
Pn313
Reserved —
—
—
—
Pn314
Reserved —
—
—
—
Pn315
Reserved —
—
—
—
Pn316
Internal speed 1
rpm
-6000~6000
100
Immediately
Pn317
Internal speed 2
rpm
-6000~6000 200 Immediately
Pn318
Internal speed 3
rpm
-6000~6000 300 Immediately
Pn319
Internal speed 4
rpm
-6000~6000 -100 Immediately
Pn320
Internal speed 5
rpm
-6000~6000 -200 Immediately
Pn321
Internal speed 6
rpm
-6000~6000 -300 Immediately
Pn322
Internal speed 7
rpm
-6000~6000 500 Immediately
Pn400
Torque reference gain
0.1V/100% 10~100
33 Immediately
Pn401
Forward torque internal limit
○
1
% 0~300
300
Immediately
Pn402
Reverse torque internal limit
○
1
% 0~300
300
Immediately
Pn403
Forward external torque limit
○
1
% 0~300
100
Immediately
Pn404
Reverse external torque limit
○
1
% 0~300
100
Immediately
Pn405
Plug braking torque limit
%
0~300
300
Immediately
Pn406
Speed limit during torque control
rpm
0~6000
1500
Immediately
Pn407
Notch filter 1 frequency
Hz 50~5000
5000
Immediately
Pn408
Notch filter 1 depth
— 0~11 1
Immediately
Pn409
Notch filter 2 frequency
Hz 50~5000
5000
Immediately
Pn410
Notch filter 2 depth
— 0~11 1
Immediately
Pn411
Low frequency jitter frequency
0.1Hz
50~500
100
Immediately
Pn412
Low frequency jitter damp
—
0~200
25
Immediately
Pn413
Torque control delay time
0.1ms 1~2000 100 Immediately
Pn414
Torque control speed hysteresis rpm
10~1000
50
Immediately
Pn415
Analog torque given zero bias
10mv
-1000~1000
0
Immediately
Pn500
Positioning error
Puls
0~5000
10
Immediately
Pn501
Coincidence difference
rpm
0~100
10
Immediately
Pn502
Zero clamp speed
rpm
0~3000
10
Immediately
Pn503
Rotation detection speed TGON
rpm
0~3000
20
Immediately
Pn504
Offset counter overflow alarm
256Puls 1~32767 1024 Immediately
Pn505
Servo ON waiting time
ms
-2000~2000
0
Immediately
Pn506
Basic waiting flow
10ms
0~500
0
Immediately
Pn507
Brake waiting speed
rpm
10~100
100
Immediately
Pn508
Brake waiting time
10ms
10~100
50
Immediately
Pn509
Allocate input signal to terminal
—
0~0xFFFF
0x3210
After restart
Pn510
Allocate input signal to terminal
—
0~0xFFFF
0x7654
After restart
Pn511
Allocate output signal to terminal
—
0~0x0999
0x0210
After restart
Pn512
Bus control input node low-bit enable
—
0~1111 0
Immediately
Pn513
Bus control input node low-bit enable
—
0~1111 0
Immediately
Summary of Contents for pronet series
Page 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Page 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Page 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Page 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Page 193: ......