ProNet
Series
AC Servo User's Manual
- 186 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
[1] Homing in the reverse direction
Pn689.1 Search C-Pulse Mode
[0] Return to search C-Pulse when homing
[1] Directly search C-Pulse when homing
Pn689.2 Homing trigger starting mode
[0] Homing function disabled
[1] Homing triggered by SHOM signal (rising edge)
Pn689.3 Reserved
Pn690
Number of error
pulses during homing
Immediately P
unit
:
10000P
Pn691
Number of error
pulses during homing
Immediately P
unit
:
1P
Pn700
Hex After
restart
ALL
Pn700.0 MODBUS communication baud rate
[0] 4800bps
[1] 9600bps
[2] 19200bps
Pn700.1 MODBUS protocol selection
[0] 7
,
N
,
2
(
MODBUS,ASCII
)
[1] 7
,
E
,
1
(
MODBUS,ASCII
)
[2] 7
,
O
,
1
(
MODBUS,ASCII
)
[3] 8
,
N
,
2
(
MODBUS,ASCII
)
[4] 8
,
E
,
1
(
MODBUS,ASCII
)
[5] 8
,
O
,
1
(
MODBUS,ASCII
)
[6] 8
,
N
,
2
(
MODBUS,RTU
)
[7] 8
,
E
,
1
(
MODBUS,RTU
)
[8] 8
,
O
,
1
(
MODBUS,RTU
)
Pn700.2 Communication protocol selection
[0]
No protocol SCI communication
[1] MODBUS SCI communication
Pn700.3 Reserved
Pn701
MODBUS
Axis
address
After restart
ALL
Axis address of MODBUS protocol communication
Pn702
Reserved
—
—
—
Pn703
CAN communication
speed
After restart
ALL
Pn703.0 CAN communication baud rate
[0] 50Kbps
[1] 100Kbps
[2] 125Kbps
[3] 250Kbps
[4] 500Kbps
[5] 1Mbps
Pn704
CAN communication
contact
After restart
ALL
CANopen Aix address of communication
Pn840
Hex After
restart
ALL
Pn840.0
Encoder model selection
[0]-[2] Reserved
(
For factory using
)
[3] 17-bit absolute encoder
[4] 17-bit incremental encoder
[5] Resolver
Summary of Contents for pronet series
Page 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Page 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Page 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Page 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Page 193: ......