ProNet
Series
AC Servo User's Manual
- 92 -
4.6 Operating Using Position Control
Set the following parameters for position control using pulse trains.
Parameter Meaning
Pn005
H
.□□
1
□
Control mode selection
:
position control (pulse train reference)
A block diagram for position control is shown as below.
Differential
Feed forward
B
A
Feed forward
filter time
constant
Offset
Positioning
complete
Current loop
Speed loop
K
P
Error counter
Smoothing
×1
×2
×4
dividing
×4
B
A
Servodrive(in position control)
Pn112
Pn201
Pn202
Pn113
Pn111
Pn500
Pn004.2
Pn204
Pn201
Pn202
Pn200
Reference pulse
PG signal output
Pn104
M
PG
Servomotor
Encoder
-
+
+
+
+
4.6.1 Basic Setting in Position Control
(1)Setting a reference pulse sign
Type
Signal Name
Connector Pin Number
Name
Input
PULS
CN1-30
Reference pulse input
/PULS
CN1-31
Reference pulse input
SIGN
CN1-32
Reference sign input
/SIGN
CN1-33
Reference sign input
(2)Setting reference input filter for open collector signal
Pn006 0
□□□
when pulse is difference input, servo receiving pulse frequency
≤
4M
1
□□□
when pulse is difference input, servo receiving pulse frequency
≤
650K
2
□□□
when pulse is difference input, servo receiving pulse frequency
≤
150K
Summary of Contents for pronet series
Page 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Page 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Page 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Page 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Page 193: ......