ProNet
Series
AC Servo User's Manual
- 103 -
4.6.7 Reference Pulse Inhibit Function (INHIBIT)
(1)Description
This function inhibits the servo drive from counting input pulses during position control.
The servomotor remains locked (clamped) while pulses are inhibited.
Error Counter
+
-
Feedback pulse
OFF
ON
Pn005.1
Pn005=H.
□□
1
□
Pn005=H.
□□B□
Reference pulse
/P-CON
/P-CON
Servodrive
(2)Setting Parameters
Parameter Meaning
Pn005
H.□□B□
Control mode selection
:
position control(pulse train reference)
⇔
INHIBIT
■
Inhibit(INHIBIT) switching condition
·
/P-CON signal ON (low level)
(3)Setting Input Signals
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Input /P-CON
CN1-15
ON(low level)
Turns the INHIBIT function ON.
(Inhibit the servo drive from counting reference
pulses)
OFF(high level)
Turns the INHIBIT function OFF.
(Counters reference pulses.)
Summary of Contents for pronet series
Page 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Page 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Page 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Page 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Page 193: ......