Self-Test Error Messages,
Continued
Format
Meaning
ff
Current software revision
gg
Current channel under test (1, 2, 3)
hh
Current electrical interface
ii
Internal loopback mode (0=internal,
1=external)
jj
External channel count
kkkk
Current SCC mode
llll
Current protocol
mmmm
Data size
nnnn
Current channel speed
oooo
Address low
pppp
Address high
qqqq
Expected data
rrrr
Actual data
Extended Error Format 0007:
This format is used by the DSW21 communications device reset
test. The reset test only returns a timeout status if it does not get
a posted interrupt controller.
020 0007 00070000 00000000 00000000 00000000 00000000 00000000
000000000
Format
Meaning
020
The FRU for the DSW21 communications
device
0007
The format type
00070000
The currently running reset test
Continued on next page