Self-Test Error Messages,
Continued
Table A–14
(Continued) NI Self-Test Error Codes
Decimal
Hexadecimal Meaning
72
48
SGEC Chip self-test: Self-Test
loopback error
74
4A
SGEC Initialization: Setup frame
send failure
76
4C
SGEC Interrupts: initialization failed
78
4E
SGEC Interrupts: transmit failed
80
50
SGEC Interrupts: receive failed
82
52
SGEC Interrupts: packet comparison
failed
84
54
SGEC Interrupts: NI ISR not entered
86
56
SGEC Interrupts: NI ISR entered
multiple times
88
58
SGEC CRC: initialization failed
90
5A
SGEC CRC: transmit failed
92
5C
SGEC CRC: receive failed
94
5E
SGEC CRC: packet comparison failed
96
60
SGEC CRC: SGEC generated bad
CRC
98
62
SGEC CRC: SGEC rejected good CRC
100
64
SGEC CRC: SGEC accepted bad CRC
102
66
SGEC CRC: Other error
104
68
SGEC Collision: initialization failed
106
6A
SGEC Collision: unknown transmit
error
108
6C
SGEC Collision: RETRY not flagged
110
6E
SGEC Collision: transmitter disabled
Continued on next page
A–24