Self-Test Error Messages,
Continued
Table A–20
(Continued) TURBOchannel Adapter Self-Test
Error Codes
Decimal
Hexadecimal
Meaning
0010
000A
FIFO Not empty after retrieving
data
0012
000C
Data read from FIFO does not match
loaded data
0014
000E
Forced invalid reference error not
seen
0016
0010
Forced ERROR condition not seen
0018
0012
TCA Interrupt at VAX INT_REG not
set
0020
0014
Interrupt bit on TCA not set
0022
0016
ISR Was not entered on interrupt
0024
0018
FIFO Data was bad after DMA
TRIGGER read operation
0026
001A
FIFO Data does not match loaded
data after DMA TRIGGER write
The TURBOchannel adapter self-test does not display extended
error information when an error occurs. Enter the SHOW ERROR
command to view the extended error information.
TURBOchannel error codes appear in the following format:
?? 013 13 TCA XXXX
The
XXXX
refers to the error code format.
Errors reported directly from the console are in decimal
format.
Errors displayed in response to the SHOW ERROR command
are in hexadecimal format.
Continued on next page
A–56