Self-Test Error Messages,
Continued
Table A–15
(Continued) SCSI Self-Test Error Codes
Decimal
Hexadecimal Meaning
66
42
SCSI Map Error Test, Map Error Will
Not Set.
68
44
SCSI Map Error Test, Parity Error
Will Not Clear.
70
46
SCSI Map Error Test, Prom Function
has Failed.
80
50
SCSI Prom Function has failed.
82
52
SCSI Init Driver has failed.
The SCSI self-test also returns extended error information when
an error occurs. This information is available by entering the
SHOW ERROR command. The extended error codes can be of the
following types:
EXTENDED ERROR FORMAT 1(h):
This error format is used by the register test.
001 0001 aaaaaaaa bbbbbbbb cccccccc dddddddd
Format
Meaning
aaaaaaaa
The error code
bbbbbbbb
Address of register or location being accessed
cccccccc
Expected data or data written
dddddddd
Actual data or data read
Continued on next page
A–30