Self-Test Error Messages,
Continued
Table A–10
(Continued) FPU Self-Test Error Codes
Decimal
Hexadecimal Meaning
3586
E02
TSTF Instruction test has failed.
3588
E04
Unexpected Exception has occurred
during TSTF test.
The FPU test displays extended error information when an error
occurs. Enter the SHOW ERROR Command to view the extended
error information. The extended error formats are shown in the
following examples.
Extended Error Format:
001 000 VVVVVVVV EEEEEEEE EEEEEEEE EEEEEEEE EEEEEEEE EEEEEEEE
EEEEEEEE
Format
Meaning
VVVVVVVV
The vector of the unexpected interrupt
EEEEEEEE
Other exception data. This is only printed on
machine checks and arithmetic traps.
Table A–11 lists the vectors that the floating point test detect
unexpected interrupts.
Table A–11 FP Exception Vectors
Vector
Description
004
Machine check vector number
010
Privileged instruction vector
014
Customer reserved instruction vector
Continued on next page
A–20