Self-Test Error Messages,
Continued
The initialization object is optional, therefore a TURBOchannel
option may or may not have an initialization function. No error
occurs if an option does not have an initialization object.
MIPS/REX
Emulator
Errors
The emulator’s function is to execute the tests. While an error
status code is maintained during testing, the emulator does not
diagnose TURBOchannel hardware failures. Error messages
should be printed by the option, using the format:
?TFL: #/test [message]
Emulator Error
Messages
Presently, there are only three MIPS/REX Emulator error
messages. Each message, a description, and recommended
corrective action follow.
Message
ERR-MIPS - DID NOT FIND ROM IN SLOT nn
Description
Emulator cannot read the ROM header in slot nn.
Continued on next page
A–63