System Test Monitor,
Continued
Burst Mode - Performs in the same way as functional mode
except the lines are tested at 19.2K baud, 8-bit characters, and
parity is odd.
The following is a example of the DZ System test error. This error
code means that not all characters were received on line 1 and
line 2.
?? 001 3 DZ 0220
The following is an example of the DZ system test summary
screen. The first column lists the serial line number that
corresponds to the following devices:
Line 0
Keyboard port
Line 1
Mouse/Pointing device port
Line 2
Communications port
Line 3
Printer/Console port
Line L_Param Chr_Xmt Chr_Rec
Error
---- ------- ------- -------
---------------------
0
1fc8
25
25
***** No Err ***
1
1fc9
25
22
?? Xfr Timedout
2
1fca
25
24
?? Xfr Timedout
3
1fcd
0
0
* Not Tstd - Cons
Continued on next page
5–37