Self-Test Error Messages,
Continued
Table A–9
(Continued) MEM SIM Module FRU Values
FRU
(decimal)
SIM
Module
BANK
046
1H
1
047
0D
0
FPU
Table A–10 lists the floating point diagnostic decimal and
hexadecimal error codes.
Table A–10 FPU Self-Test Error Codes
Decimal
Hexadecimal Meaning
258
102
MOVF Instruction test has failed.
260
104
Unexpected Exception has occurred
during MOVF test.
514
202
MNEGF Instruction test has failed.
516
204
Unexpected Exception has occurred
during MNEGF test.
770
302
ACBF Instruction test has failed.
772
304
Unexpected Exception has occurred
during ACBF test.
1026
402
ADDF2/ADDF3 Instruction test has
failed.
1028
404
Unexpected Exception has occurred
during ADDFx test.
1282
502
CMPF Instruction test has failed.
1284
504
Unexpected Exception has occurred
during CMPF test.
Continued on next page
A–18