Setting Up the Diagnostic Environment,
Continued
Setting the
Diagnostic
Environment
To set the diagnostic environment, enter one of the console
commands listed in Table 5–3. Note that all diagnostic
environments except DIAGENV 1 require a loopback connector.
Table 5–3 SET DIAGENV Command
Command
Result
SET DIAGENV 1
Resets environment to customer mode.
SET DIAGENV 2
Sets environment to Digital Services
mode.
SET DIAGENV 3
Sets environment to manufacturing
mode.
SET DIAGENV
80000001
Sets environment to loop on error in
Digital Services mode.
SET DIAGENV
80000002
Sets environment to loop on error in
manufacturing mode.
Example:
These are examples of setting and showing the diagnostic
environment.
>>>SET DIAGENV 2
DIAGENV = 2
>>>SHOW DIAGENV
DIAGENV = 2
5–14