Testing the VAXstation 4000 Model 90 System,
Continued
Step
Action
2
Display the system device configuration by using the
SHOW CONFIG command (see the System Preparation
section). Compare the latest configuration display with
the configuration display you viewed during system
preparation. You should see the new device and the
other devices present in the system. Verify that no error
messages appear on the monitor screen.
3
Verify that all devices are interacting correctly by using
the TEST 100 command to run the system exerciser.
4
Verify that drives are set to the correct SCSI IDs using
the SHOW DEVICE command.
5
If problems occur, be sure that:
All cables inside and outside the system are
connected.
All modules are fully seated in their connectors.
SCSI IDs are set correctly. There should not be any
duplicate SCSI IDs. Refer to Table 6–2 for standard
SCSI ID settings.
Continued on next page