Table A–19 Synch Comm Device Test Error Codes
Decimal
Hexadecimal Meaning
1
1
Self-Test was unsuccessful
2
2
Transmit underflow
4
4
Transmitter busy
6
6
Receiver busy
8
8
Transmitter error
10
A
Carrier detect loss
Sync Comm Receive Failures
12
C
Receive overflow
14
E
Receive CRC error
16
10
Receive abort
18
12
Receive non-octet aligned
20
14
Receive parity error
22
16
Receive frame error
24
18
Receive length too large
26
1C
Receive DLE follow
30
1E
No external loopback connector
32
20
Invalid test specified
34
22
Timeout waiting for response
36
24
Comm module timeout waiting
Continued on next page