System Test Error Messages,
Continued
There are 9 error codes possible for each line:
1 - not all characters transmitted
2 - 1st character not received
3 - timeout
4 - more characters received than expected
5 - parity error
6 - framing error
7 - overrun error
8 - data compare error These errors are translated by
the summary screen.
The summary screen for the DZ module has the following format
for each line:
Line
L_Param
Chr_Xmt
Chr_Rec
Error
Format
Meaning
Line
Line number
L_Param
Line parameters
Chr_Xmt
Last character transmitted
Chr_Rec
Last character received
Error
Text message for error code from main screen
for this line
Network
Interface
The following is an example of the NI error message format.
?? 9 NI
X
00YY
0 00:00:00:00
X is the source of the error:
1 - Test
2 - System Test Monitor
3 - Device Driver
Continued on next page
A–87