Self-Test Error Messages,
Continued
Format
Meaning
jj
External channel count
kkkk
Current SCC mode
llll
Current protocol
mmmm
Data size
nnnn
Current channel speed
oooo
Address low
pppp
Address high
qqqq
Expected data
rrrr
Actual data
Extended Error Format 0004:
This format is used by the DSW21 communications device
interrupt test.
020 0004 aaaabbbb ccddeeff gghhiijj kkkkllll mmmmnnnn oooopppp
qqqqrrrr
Format
Meaning
020
The FRU for the DSW21 communications
device
0004
Format type for the self-test
aaaa
Test status
bbbb
MC68302 diagnostic test number
cc
Cable code for channel 1 SCC1
dd
Cable code for channel 2 SCC2
ee
Current hardware revision
ff
Current software revision
gg
Current channel under test (1, 2, 3)
hh
Current electrical interface
Continued on next page