Troubleshooting,
Continued
Table C–5
(Continued) Drive Problems
Symptom
Possible Cause
Corrective Action
Two SCSI
identifiers are
set to the same
ID number.
Reset each SCSI ID to a
unique number.
Loose cables.
Verify that all cables are
securely connected.
Defective drive.
Run diagnostics to isolate
fault. Replace FRU.
Drive does not
work.
Two SCSI
identifiers are
set to the same
ID number.
Reset each SCSI ID to a
unique number.
Loose cables.
Verify that all cables are
securely connected.
Defective drive.
Run diagnostics to isolate
fault. Replace FRU.
Network
Problems
Table C–6 Network Problems
Symptom
Possible Cause
Corrective Action
NI Error
message displays
when verifying
Ethernet.
No ThinWire
or Thickwire
terminator
or cable was
installed.
Attach a ThinWire
or standard Ethernet
terminator.
Continued on next page
C–10