Self-Test Error Messages,
Continued
Extended Error Format 0008:
This format is used by the synchronous communication option
null request.
020 0008 0008 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000
Format
Meaning
020
The FRU for the DSW21 communications
device
0008
Format type
0008
The currently running null request
Extended Error Format 0009:
This format is used by the DSW21 communications device when
an exception occurs.
020 0009 00EEaaaa bbbbcccc dddd0000 00000000 0000eeee ffffgggg
00000000
Format
Meaning
020
The FRU for the DSW21 communications
device
0009
Format type
aaaa
Command status register
bbbb
Stack pointer high
cccc
Exception vector
dddd
Stack pointer low
eeee
Status register
ffff
PC low
gggg
PC high
Continued on next page