PowerVault ML6000 Maintenance Guide
37
Required tools:
None
1
If your library is 14U or taller, install it in a rack. See
Using the Rack-mount Kit to Install a Library in a
Rack
on page 108 for instructions. The instructions include procedures for removing and replacing tape
drives.
2
For each FC I/O blade installed in a 9U expansion module, connect the 9U expansion module
containing the FC I/O blade(s) to a port in the Ethernet hub on the LCB:
•
If the FC I/O blade is installed in the bottom bay of the expansion module, connect one end of
an Ethernet cable to the Ethernet port labeled
LOWER
in the lower right corner of the expansion
module. Connect the other end of the cable to a port in the Ethernet hub on the LCB.
•
If the FC I/O blade is installed in the upper bay of the expansion module, connect one end of
an Ethernet cable to the Ethernet port labeled
UPPER
in the lower right corner of the expansion
module. Connect the other end of the cable to a port in the Ethernet hub on the LCB.
•
Follow the instructions in
Cable Management Guidelines
on page 40 for best practices in
routing the Ethernet cables.
3
Remove and discard the necessary number of the black rubber protective covers from the ports on the
FC I/O blades.
4
Carefully unwrap the FC cables and remove the two white plastic protective caps from each end of the
cable.
5
Connect the FC cable to one of the following initiator ports on the FC I/O blade: 3, 4, 5, or 6. When you
choose the port, take into account the location of any other tape drives that you plan to connect to the
same FC I/O blade. See
Cable Management Guidelines
on page 40 for best-practice guidelines for
cabling a library.
6
Insert the other end of the FC cable into the FC port on the FC tape drive.
7
Repeat the above steps for each FC drive you want to connect to the I/O blade. Do not connect any of
these FC cables to ports 1 or 2 on the FC I/O blade.
8
Connect the host(s) to ports 1 and/or 2 on the FC I/O blade.
WARNING
ALL LIBRARIES TALLER THAN 14U MUST BE INSTALLED IN A RACK
HAVING A MAIN PROTECTIVE EARTHING (GROUNDING) TERMINAL,
AND POWER MUST BE SUPPLIED VIA AN INDUSTRIAL PLUG AND
SOCKET-OUTLET AND/OR AN APPLIANCE COUPLER COMPLYING
WITH IEC 60309 (OR AN EQUIVALENT NATIONAL STANDARD) AND
HAVING A PROTECTIVE EARTH (GROUND) CONDUCTOR WITH A
CROSS SECTIONAL AREA OF AT LEAST 1.5 MM
2
(14 AWG).
TO ENSURE PROPER AIRFLOW AND ACCESS SPACE, ALLOW 60 CM
(24 INCHES) IN THE FRONT AND BACK OF THE LIBRARY.
Note
Pay attention to where the operator panel is positioned in the rack for optimum
usability.
Note
Without these Ethernet cables connected, the I/O blades will not work.
CAUTION
FC cables will be damaged if they are bent at more than a four-inch
arc.
Summary of Contents for PowerVault ML6000
Page 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Page 14: ...xiv Tables ...
Page 18: ...xviii Figures ...
Page 452: ...434 Troubleshooting the Tape Library ...
Page 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Page 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Page 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Page 478: ...460 Library Drawings Figure 59 LCB Functions ...
Page 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Page 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Page 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Page 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Page 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Page 486: ...468 Library Drawings ...
Page 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...