382
Troubleshooting the Tape Library
8
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR032 - Resolve Drive Control Path Failure
This DR provides customer resolution steps for
T070
on page 268.
Problem: A library control path through a drive sled has failed. It is likely that a tape drive sled failure is being
reported as a separate problem.
It may be possible to reestablish the control path by resetting the drive sled. In libraries with more than one
tape drive, you have the option to use an alternate tape drive as the control path if your host connection
architecture permits it.
Changing the control path can be a temporary workaround until the original tape drive problem is corrected
or the change is applied permanently.
1
Close this ticket and attempt to reestablish the control path by pulling the drive sled out of the library,
waiting for the robot to scan the tape drive location, then reinserting the drive sled and securing the
thumbscrews.
2
Wait for the tape drive to initialize and become ready.
3
If this ticket reoccurs, continue to Step 4 to switch the control path; otherwise, the problem is resolved
and no further action is required.
4
Use the functions on the
Setup > Control Path
menu to switch the control path to an alternate tape
drive. See your User’s Guide for detailed instructions.Whether you change the control path or not, you
may close this RAS ticket.
5
Resolve any other associated tape drive problem tickets.
6
You have three options:
a. Select
Close
to close the ticket now.
b. Select
Exit
to leave the ticket open for future troubleshooting.
c. Select
Back
to return to the Diagnostic Resolution.
DR033 - Resolve Drive Sled Auto-Level Failure
This DR provides customer resolution steps for
T074
on page 272.
Problem: The library attempted to change the firmware level in a drive sled, but the process failed.
1
Using the tape drive coordinate from the problem
Details
screen, identify the tape drive sled that failed.
2
After you have located the tape drive on the rear of the library, unscrew the thumbscrews and pull the
drive sled out of the library completely for at least 30 seconds.
3
Close the ticket, re-insert the drive sled, and tighten the thumbscrews.
4
The library should now attempt to discover and initialize the tape drive again.
5
If this second attempt to auto-level the drive sled firmware level fails, contact Service for assistance.
Summary of Contents for PowerVault ML6000
Page 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Page 14: ...xiv Tables ...
Page 18: ...xviii Figures ...
Page 452: ...434 Troubleshooting the Tape Library ...
Page 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Page 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Page 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Page 478: ...460 Library Drawings Figure 59 LCB Functions ...
Page 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Page 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Page 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Page 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Page 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Page 486: ...468 Library Drawings ...
Page 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...