316
Troubleshooting the Tape Library
T116
T116 - Robotics Firmware Image Error
Description
This RAS ticket applies to
Model 2 robots only
(see
How to Determine Which
Robot Your Library Contains
on page 165).
GUI Description:
The robotics firmware auto-level process cannot be
performed because necessary files are missing or corrupted.
Explanation:
The library is unable to attempt the robotics firmware
autoleveling process. In this case, the robotics firmware autolevel is not
attempted, and the robotics subsystem is left in the “not ready” state.
Detection Scenarios
• A necessary autolevel file is missing in the library firmware.
• A necessary autolevel file failed validation.
Root Cause
Firmware corruption.
Service Resolution
Steps
Perform
DR084 - Resolve Robotics Firmware Image Error
on page 404.
Possible CRUs/FRUs
None
Summary of Contents for PowerVault ML6000
Page 1: ...w w w d e l l c o m s u p p o r t d e l l c o m MaintenanceGuide Dell PowerVault ML6000 ...
Page 14: ...xiv Tables ...
Page 18: ...xviii Figures ...
Page 452: ...434 Troubleshooting the Tape Library ...
Page 456: ...438 Library Drawings Library Rear View Figure 32 ML6020 Rear View ...
Page 468: ...450 Library Drawings Power Supplies Figure 49 Power Supplies ...
Page 477: ...PowerVault ML6000 Maintenance Guide 459 Figure 58 Electrical System 5U Library Control Module ...
Page 478: ...460 Library Drawings Figure 59 LCB Functions ...
Page 479: ...PowerVault ML6000 Maintenance Guide 461 ...
Page 482: ...464 Library Drawings Figure 64 Fan Control Board ...
Page 483: ...PowerVault ML6000 Maintenance Guide 465 Figure 65 Library Cables ...
Page 484: ...466 Library Drawings Figure 66 Library System Grounding ...
Page 485: ...PowerVault ML6000 Maintenance Guide 467 Figure 67 Library Power System ...
Page 486: ...468 Library Drawings ...
Page 494: ...476 Glossary Y axis Y position The vertical position of the library s robotic arm ...