![DAP Technology 1394 Operation Manual Download Page 393](http://html.mh-extra.com/html/dap-technology/1394/1394_operation-manual_509853393.webp)
Hardware
393
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
based on the latest Gen4 concept. Each analyzer card in fact combines three FireSpy analyzers in one
single instrument.
The PCIe's format takes flexibility to a higher level and addresses the industries growing support for this
data interface. This solution enables users to install the FireSpy hardware in any modern PC that has at
least one 4-lane PCIe slot available. This allows for installation of the FireSpy in developers existing PCs
or installing the analyzer in a rugged field service laptop or lunchbox computer.
The FireSpy3x22bT have three 1394 nodes connected to three synchronized analysis engines. They are
controlled by a dual core ARM processor running at 667MHz. Each node is connected to two 1394 ports.
Two ports of each 1394 node are connected to a LEMO connector.
The FireSpy3x22bT are equipped with 5 GB internal memory and extensive hardware filtering and trigger
possibilities. The analyzer can be connected into a host computer using its PCIe interface. On the host
you can control the FireSpy using a graphical user interface to analyze and display the bus traffic in a
user-friendly way; or you can use the API to program your own control software.
24.1.4.1. Main Feature Summary
GENERAL
·
IEEE 1394-2008 Beta compliant
·
Supports S100-S800 transfer rates depending on exact model
·
Connects to host using PCIe interface
·
5GByte memory for embedded OS and packet and data storage
·
Firmware field upgradeable to enable future expansions
·
AUX connector for:
o
Trigger input and output functions
o
Recording external events
o
Time synchronization
·
GUI and API for Windows
TM
Operating Systems
MONITOR
·
Displays bus activity:
o
isochronous packets
o
all types of asynchronous packets
o
all types of PHY packets
o
all types of acknowledge packets
o
several types of Errors
·
Counts packets according to type, speed, ack and error condition
·
Counts number of bus resets
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...