information that was send during the login command and is not resend for a reconnect command. This
missing information can be added manually, or you should make sure the SBP unit was disconnected for
a period longer than 20 seconds, so that a login command will be recorded.
Manually inputting SBP information
If no Configuration-ROM reads login-command is recorded, you will need to input this information
manually. Also if only part of this information can be found automatically, you will need to add information
manually. You can do this in the 'Protocol Settings' dialog. It can be opened by clicking the 'Protocol
Settings' button on the toolbar (see below). This dialog shows information used by the all-protocol
analyzers. It initially shows all information that it found automatically and you can change or add
information manually. See the description of the 'SBP-Protocol Settings' below for more information.
17.1.2. Details
The Protocol View consists of a toolbar on the top, with three parts below it: the 'relations' pane, the
details pane and the 'transactions and packets' pane.
17.1.2.1. Toolbar
At the top of the Protocol View you will find a toolbar with a few buttons:
In front of the name 'Protocol View' a star '*' will be displayed if the protocol-analysis settings have been
modified.
Protocol Settings
When clicking this button, the 'Protocol Settings' dialog will be displayed. It shows information used by the
protocol analyzers. It initially shows information that was found automatically and you will be able to
change or add information. See 'SBP-Protocol Settings' below for more information.
Go to next item with warning(s)
When clicking this button, the next item that contains one or more warnings will be selected.
Go to next item with error(s)
When clicking this button, the next item that contains one or more errors will be selected.
Show Transactions and Packets
This button toggles the display of the right pane at the right side of the Protocol View.
Triple Analyzers
For triple Analyzers the Toolbar looks as follows:
It contains the following additional control:
Analyzer node select control
With this control you are able to select the protocol analysis result of each supported Analyzer node.
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...