In the example above, an isochronous packet was selected and its details are displayed in the middle part
as described above. The extra display, the 'Isochronous source packet' part, will display the isochronous
source packet corresponding to the selected isochronous. As defined in the IEC61883 standard,
isochronous streams are build from isochronous source packets. The data of one isochronous source
packet can consist of data from a part of an isochronous packet, or from one or more complete
isochronous packets.
15.1.2. Details
The AV/C-Protocol View consists of a toolbar on the top, with a maximum of four parts below it: the
'relations' pane, the 'Transaction/Isochronous-packet data' (details) pane, the 'transactions and packets'
pane and optionally the 'Isochronous source packets' pane.
15.1.2.1. Toolbar
At the top of the Protocol View you will find a toolbar with a few buttons:
In front of the name 'Protocol View' a star '*' will be displayed if the protocol analysis settings have been
modified.
Protocol Settings
When clicking this button, the 'Protocol Settings' dialog will be displayed. It shows information used by the
protocol analyzers. It initially shows information that was found automatically and you will be able to
change or add information. See 'AV/C-Protocol Settings' below for more information.
Go to next item with warning(s)
When clicking this button, the next item that contains one or more warnings will be selected.
Go to next item with error(s)
When clicking this button, the next item that contains one or more errors will be selected.
Show Transactions and Packets
This button toggles the display of the right pane on the right side of the Protocol View.
Toggle source display on/off
With this button an optional 'Isochronous source packets' pane can be switched on or off. If switched on, it
is added to the left of the 'Transaction/Isochronous-packet data' pane. See below for a description of this
pane.
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...