![DAP Technology 1394 Operation Manual Download Page 220](http://html.mh-extra.com/html/dap-technology/1394/1394_operation-manual_509853220.webp)
Filter/Trigger
220
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
In the example above, the jump-condition is only true for CycleStart packets.
·
other Packets ...: If this option is selected, additional check boxes appear where you can
specify some special packet types or some packet errors. If a packet was detected with a
type for which the corresponding checkbox is checked or with an error for which the
corresponding checkbox is checked, the jump-condition is true.
In the example above, the jump-condition is true for packets with an error.
·
Last Wait was Ack ...: This option is used to specify an Acknowledge condition. If the last
Wait was ended because of the detection of an Packet or Event, then the result of the
jump-condition is always false. The three elipses indicate that additional sub-selections are
possible. When selecting this option, the additional sub-selection options appear at the right
top of the Jump Properties box. See example below.