Custom Protocols
333
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
'relation' pane are colored gray.
19.3.5. Custom Protocol Settings
When clicking the 'Protocol Settings' button in the toolbar of the Protocol View, the 'Protocol Settings'
dialog will be displayed. This dialog shows information used by the protocol analyzer to find and correctly
analyze the transactions. For each supported protocol, including custom-made protocols, there is a tab
page with protocol-specific settings. The dialog will be initialized with all information that can be found
automatically. If this is not enough for a correct analysis you can add this information manually.
An example of the dialog is shown below.
In the dialog you see an upper part to specify one or more 'Node Specifications', and a lower part to
specify protocol-specific information. In between these two parts, general options can be selected.
For a correct analysis the Unit information of the device which support the custom-made protocol to be
analyzed must be present To be able to specify a Unit, you will first need to specify the device (Node
Specification) the Unit is a part of.
For more information about Node Specifications and the protocol-independent part of the Protocol
Settings, see Protocol Settings. For the custom-made protocol-specific settings, see below.
Node Specifications
If no custom-made protocol Units were found automatically, you have to specify one or more Units
manually. Before you can specify a Unit you have to specify the node the Unit is part of, using a Node
Specification. When the device which support the custom-made protocol is still connected to the bus after
recording, you can use the 'Search Current' button to automatically find these Units. Adding such a Unit
will create a Node Specification and Unit. The created Node Specification will be filled automatically when
possible. You probably will have to select correct nodes for some reset segments. Make sure you have
selected the correct node for those reset segments for which transaction and packets are recorded that
you want to analyze. For more information on Node Specifications, see Protocol Settings.
General options
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...