![DAP Technology 1394 Operation Manual Download Page 120](http://html.mh-extra.com/html/dap-technology/1394/1394_operation-manual_509853120.webp)
Recorder
120
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
Decimal and hexadecimal numbers can be entered decimal or hexadecimal. For fields with
symbolic values, a combo box will be displayed when clicking on the value so that a value can be
chosen. You can change this behaviour by selecting another display form (overruling the automatic
form) using the right mouse button as described below.
If you clear this field, the compare type in the Cond. columns will be removed too.
Together with the compare type from the Cond. column it specifies the condition the packet field
should have to fit the set.
·
Mask. Before the packet field is compared with the Value, a logical-and is performed with this Mask
value. It can be used to mask one or more bits before the compare is done. For each bit in the
mask with value 0, the corresponding bit in the packet field and the corresponding bit in the
specified Value will be cleared before they are compared.
Using a right mouse click in the Field table you can popup a menu to select one of the following
options:
·
display form. You can select if the value of the fields should be displayed Hexadecimal, Decimal or
Automatic. Automatic (default) means that the format will determine the display form for each field
separately. One of the automatic forms can be a symbolic value.
·
Select All. With this option you can quickly select all fields in the table.
·
Import and Export. With this option you can import or export the selected field(s) or all fields.
If you choose to import, a file dialog is presented. You can select to import from a hex data file
(*.hex) file or quadlet data file *.qdl file. See File Formats for more information on these formats.
If you choose to export, you can select the type of export in a little dialog and then with a file dialog
you can select a file to export to.
·
Hex/Ascii edit. With this option you can edit the selected field(s) or all fields using a hex/ascii
editor.
·
Layout. The formatted payload or field can be shown as a table or a layout picture. The Layout tab
shows the layout picture. The same fields are presented as in the 'Fields' tab, but now you can see the
sizes of the fields and how they are positioned in the data block. Note that reserved fields are shown
here too. Reserved fields are not shown in the 'Fields' table.
Save/Load Search dialog settings file
Your customized search criteria can be saved from and loaded to the dialog. An files has the extension of
"*.frs". Save and Load buttons are located at the bottom of the dialog.
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...