![DAP Technology 1394 Operation Manual Download Page 372](http://html.mh-extra.com/html/dap-technology/1394/1394_operation-manual_509853372.webp)
File Formats
372
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
FS Node
Speed Code
Reserved
0x03
Fields
Header Flags Data Flags
Header Size in
Quadlets
Data Size in Quadlets
Time Field
Header
Header CRC
Data
Data CRC
FS Node: Analyzer node - for Triple models (4 bits)
0: Node A
1: Node B
2: Node C
Speed Code: Transmission speed (4 bits)
0: Unknown
1: 100 Mbps
2: 200 Mbps
3: 400 Mbps
4: 800 Mbps
Fields: List of Fields, end is indicated with 0
Header Flags: 0x1 - CRC Error (4 bits)
Data Flags: 0x1 - CRC Error (4 bits)
Header Size in Quadlets: Number of Header Quadlets (6 bits)
Data Size in Quadlets: Number of Data Quadlets (including CRCs) (18 bits)
Time Field: 0, 32 or 64 bits depending on Time Format
Header: 1394 Header Contents (Quadlet aligned)
Header CRC: 1394 Header CRC (Quadlet aligned)
Data: 1394 Data Contents
Data CRC: 1394 Data CRC
23.5. Signal Definitions file
The signal definitions file format is a comma separated file (CSV), used by the Signal Monitor.
These columns have been defined:
Numb
er
What
Type
Description
Example
1
Name
ascii text
Name of signal
engine1_heartbeat
2
Channel
unsigned
integer
Channel number of this signal
10
3
MessageID unsigned
integer
The ID of the message to monitor
0
4
QuadletOff
set
unsigned
integer
Offset in the packet of the quadlet that
contains the signal.
5
5
FirstBits
unsigned
integer
Offset of the signal in bits inside a quadlet 16
6
NumBits
unsigned
integer
Number of bits that a signal occupies
16
7
SignExtend boolean
Whether or not to sign extend a value
1 or 0
8
RangeLow double
Lower boundary, used by Control Panel
-1000
9
RangeHi
double
Upper boundary, used by Control Panel
123.45
10
Resolution double
The raw value in the signal is multiplied by
this constant to create the interpreted
0.000230708
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...