![DAP Technology 1394 Operation Manual Download Page 311](http://html.mh-extra.com/html/dap-technology/1394/1394_operation-manual_509853311.webp)
Serial Bus Protocol (SBP)
311
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
In the dialog you see an upper part to specify one or more 'Node Specifications', and a lower part to
specify protocol-specific information. In between these two parts, general options can be selected.
In the protocol-specific part one or more 'Units' can be specified for each protocol. For a correct analysis
the Unit information of the SBP device to be analyzed must be present. And if no login command was
recorded, you also need to specify an initial login. To be able to specify a Unit, you will first need to
specify the device (Node Specification) the Unit is part of.
For more information about Node Specifications and the protocol-independent part of the
, see Protocol Settings. For the SBP-protocol-specific settings, see below.
Node Specifications
If no SBP Units were found automatically, you have to specify one or more Units manually. Before you
can specify a Unit you have to specify the node the Unit is part of, using a Node Specification. When the
SBP device is still connected to the bus after recording, you can use the 'Search Current' button to
automatically find SBP Units. Adding such a Unit will create a Node Specification and Unit. The created
Node Specification will be filled automatically when possible. You probably will have to select correct
nodes for some reset segments. Make sure you have selected the SBP node corrrectly for those reset
segments for which transaction and packets are recorded that you want to analyze.
General Options
Mark unhandled packets
For information about this checkbox, please see Protocol Settings.
Protocol-specific information
Enable SBP analysis
Check this box to enable the SBP analyzer. All protocol tabs in this dialog have such a checkbox, which
can be useful if a recording contains data from several protocols, and you're not interested in some of
these.
Units
In the Units table, one or more SBP Units can be specified. The information in this table normally can be
found in the Configuration ROM of the SBP node.
It consists of:
·
Unit: Using the checkbox before each Unit in the table you can enable or disable each Unit individually
for analysis. If the box is not checked, the SBP-related transactions and packets for this Unit will be
Summary of Contents for 1394
Page 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Page 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Page 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Page 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...