COPIER (Service mode for copier) > OPTION (Specification setting mode) > USER
FREG-SW
2
For R&D
IFAX-SZL
2
Setting of IFAX send size limit
Detail
To set for restricting data size at the time of IFAX transmission that does not go through the server.
With the setting to restrict the data size, there will be #830 error in the case of sending data that
exceeds the upper limit value.
In the case that the data goes through the server, the size of transmission data is always restricted.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Limited, 1: Not limited (Restriction applies when data goes through the server.)
Default Value
1
Additional Functions
Mode
Function Settings> Send> E-Mail/I-Fax Settings> Maximum Data Size for Sending
Supplement/Memo
Set the upper limit value for transmission data size in Settings/Registration menu.
IFAX-PGD
2
Set page split TX at IFAX Simple mode TX
Detail
To set to enable/disable split-data transmission on a page basis in the case that the transmission
size in IFAX Simple mode exceeds the upper limit value.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
In the case to enable split-data transmission, be sure to get approval from the user by explaining
the following:
- No guarantee for page order on the reception side
- There is a possibility of interruption of other received jobs between pages.
Display/Adj/Set Range
0 to 1
0: Disabled, 1: Enabled
Default Value
0
Related Service Mode
COPIER> OPTION> CLEANING> W-CLN-P
Additional Functions
Mode
Function Settings> Send> E-Mail/I-Fax Settings> Maximum Data Size for Sending
Supplement/Memo
Set the upper limit value for transmission data size in Settings/Registration menu.
MEAPSAFE
2
Setting of MEAP safe mode
Detail
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set safe mode for MEAP platform.
MPSF is displayed on the Control Panel in safe mode.
In safe mode, MEAP application is stopped while just the system application, which starts with
initial state, is activated. Logs for cause analysis of MEAP failure can be obtained.
Use Case
Perform system recovery processing when MEAP platform fails to be activated due to resource
confliction between MEAP applications, service registration or use order.
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Normal mode, 1: Safe mode
Default Value
0
8. Service Mode
787
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...