E196-0102-05
EEPROM communication error
Detection Description
Although write polling to the SCNR EEPROM from the DC Controller PCB (CPU) was performed
for 3 times, no response was received and timeout occurred.
Remedy
[Related parts] R1.00
- Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB
(UN05/J202)
- Harness between the DC Controller PCB (UN04/J184) and the Developing High-voltage PCB
(UN06/J241)
- Y/M/C/Bk Laser Driver PCB (UN05)
- Developing High-voltage PCB (UN06)
- DC Controller PCB (UN04)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
E196-010F-05
EEPROM communication error
Detection Description
The number of read/write job data to the SCNR EEPROM (device information) exceeded 100.
Remedy
[Remedy] Turn OFF and then ON the main power.
[Reference] Data (device information) is reset by turning OFF and then ON the main power.
E196-020F-05
EEPROM communication error
Detection Description
The number of read/write job data (device information) to the PCRG (Y) EEPROM exceeded the
specified value.
Remedy
[Remedy] Turn OFF and then ON the main power.
[Reference] Data (device information) is reset by turning OFF and then ON the main power.
E196-030F-05
EEPROM communication error
Detection Description
The number of read/write job data (device information) to the PCRG (M) EEPROM exceeded the
specified value.
Remedy
[Remedy] Turn OFF and then ON the main power.
[Reference] Data (device information) is reset by turning OFF and then ON the main power.
E196-040F-05
EEPROM communication error
Detection Description
The number of read/write job data (device information) to the PCRG (C) EEPROM exceeded the
specified value.
Remedy
[Remedy] Turn OFF and then ON the main power.
[Reference] Data (device information) is reset by turning OFF and then ON the main power.
E196-050F-05
EEPROM communication error
Detection Description
The number of read/write job data (device information) to the PCRG (Bk) EEPROM exceeded the
specified value.
Remedy
[Remedy] Turn OFF and then ON the main power.
[Reference] Data (device information) is reset by turning OFF and then ON the main power.
7. Error/Jam/Alarm
400
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...