Setting the encryption function
1. To enable this function, set "2" in the following service mode (Lv.2).
COPIER > TEST > NET-CAP > ENCDATA
• 0: Encrypted when data is extracted (factory default setting).
• 1: Not encrypted when data is extracted.
• 2: When data is extracted, a ciphertext file and a plaintext file are extracted.
The extension of extracted packet data will be "XXX.can" when encryption settings are enabled.
The extension of extracted packet data will be "XXX.cap" when encryption settings are disabled.
This setting only applies when extracting data by the USB flash drive.
NOTE:
When SST is used to collect data, both plaintext data and ciphertext data are extracted, and this setting is ignored.
Setting the payload drop function
1. To enable this setting, set "1" in the following service mode (Lv.2).
COPIER > TEST > NET-CAP > PAYLOAD
• 0: Not drop the payload (factory default settings)
• 1: Drop the payload
The obtained packet data includes a header part and data part. The header part includes data such as the TCP header and
IP header. The data part includes the actual data.
Enabling this function discards the actual payload data and extracts only the data from the header part, which has the following
effects.
• Can be used when customer data is not allowed to be extracted
• Can be used in an environment where traffic is highly overloaded
Header part
Data part
Discarded part
Packet data structure image
Setting the filter function
1. To enable this function, set "1" in the following service mode (Lv.2).
COPIER > TEST > NET-CAP > SIMPFILT
• 0: All data is collected without being filtered (factory default setting).
• 1: Data is filtered.
If this function is enabled, only packet data that includes the machine's MAC address in the packet header is captured.
Setting the startup collection function
1. To enable this function, set "1" in the following service mode (Lv.2).
COPIER > TEST > NET-CAP > PONSTART
• 0: Not automatically collect at startup (factory default setting)
• 1: Data is filtered.
If this function is enabled, only packet data that includes the machine's MAC address in the packet header is captured.
■ Saving Manual Logs
Follow the procedure shown below to save manual logs that require manual operation to the backup area of the host machine.
1. Reproduce the symptom.
6. Troubleshooting
357
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...