COPIER (Service mode for copier) > OPTION (Specification setting mode) > DSPLY-SW
CLN-SEL
1
Set of condensation prev main unit clean
Detail
To set the effect of cleaning inside the main unit for condensation prevention.
When 0 is set, cleaning inside the main unit is not executed.
When 1 to 3 is set, an item for condensation prevention is displayed in Settings/Registration, and
the level of effect of cleaning inside the main unit can be set.
As the value is larger, the effect is increased because ITB cleaning is executed more frequently,
but toner consumption and cleaning time are increased.
In the case of installation in a low temperature and high humidity environment (in winter), ask for
the user's opinion and configure the setting.
Use Case
When condensation occurs in a low temperature and high humidity environment
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Display/Adj/Set Range
0 to 3
0: OFF
1: ON (small effect, low toner consumption)
2: ON (moderate effect, moderate toner consumption)
3: ON (large effect, high toner consumption)
Default Value
0
SDTM-DSP
1
Display/hide of auto shutdown time
Detail
To set whether to display "Auto Shutdown Time" in Settings/Registration menu.
Use Case
Upon user's request
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Caution
When "Hide" is set, auto shutdown time is reset. (Auto shutdown is not performed.)
Display/Adj/Set Range
0 to 1
0: Hide, 1: Display
Default Value
It differs according to the location.
Additional Functions
Mode
Preferences> Time/Energy Settings> Auto Shutdown Time
WT-WARN
1
Dspl/hide of Wst Tonr Cntner prep mssg
Detail
To set whether to display the preparation warning message of the Waste Toner Container on the
status area of LUI.
Use Case
When there is no need to notify the preparation timing of the Waste Toner Container to the user
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Hide, 1: Display
Default Value
1
DF-DSP
1
ON/OFF ADF Maintenance Kit cntr ini scrn
Detail
To set whether to display "ADF Maintenance Kit" on the counter initialization screen in [Settings/
Registration].
Use Case
When the user does not replace the parts
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Display/Adj/Set Range
0 to 1
0: Hide, 1: Display
Default Value
1
Additional Functions
Mode
Adjustment/Maintenance> Maintenance> Initialize After Replacing Parts> ADF Maintenance Kit
8. Service Mode
734
Summary of Contents for imageRUNNER ADVANCE C255 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C355 C255 Series Service Manual ...
Page 17: ...Product Overview 1 Product Lineup 7 Option 8 Features 11 Specifications 14 Parts Name 18 ...
Page 127: ...Periodical Service 3 Periodically Replacement Parts 117 Consumable parts 118 ...
Page 154: ...4 Remove the Screws 5x 5 Remove the Rear Cover 1 4 Parts Replacement and Cleaning 143 ...
Page 257: ...1 Free the Harness 1 Harness Guide A 1x 1 A 4 Parts Replacement and Cleaning 246 ...
Page 376: ...Error Jam Alarm 7 Overview 366 EError Code 369 Jam Code 457 Alarm Code 464 ...
Page 469: ...Host Machine Cassette PS12 PS11 PS01 PS04 PS05 PS14 PS10 PS101 7 Error Jam Alarm 458 ...
Page 490: ...85 0005 For R D A Operation B Cause C Remedy 7 Error Jam Alarm 479 ...
Page 890: ...4 4x TP M3x6 5 3x 6 2x TP M3x6 7 8 9 Installation 879 ...
Page 891: ...9 1x 10 1x 11 2x 12 4x 13 9 Installation 880 ...
Page 903: ...17 9 Installation 892 ...
Page 914: ...5 6 2x Screw w washer M3x14 7 4x TP M3x6 9 Installation 903 ...
Page 923: ...3 2x 4 Short 1x 5 1x NOTE The removed screw will be used in step 7 6 1x 9 Installation 912 ...
Page 930: ...9 10 11 1x 12 13 9 Installation 919 ...
Page 931: ...14 2x 15 16 2x 17 6x 18 4x 9 Installation 920 ...
Page 932: ... Installing the NFC kit C1 1 1x 2 1x 3 TP M3x4 1x 9 Installation 921 ...